Home > Product > Polarization Maintaining Components > PM Coupler / Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter
1xN PM PLC Splitter

1xN PM PLC Splitter

GEZHI offers 1x4 1x8 1x16 1x32 PM fiber optic PLC Splitter or large selection of polarization maintaining (PM) 1xN and 2xN optical splitter. PM fibers are bonded to the PLC circuit chips using precision multi-fiber alignment techniques. Our splitter modules feature low insertion loss, low polarization dependence and high polarization extinction ratio over a wide wavelength range.
  • 1xN Polarization Maintaining PLC Splitter Module

    1310nm, 1550nm

    The Polarization Maintaining Planar Light wave Circuit (PLC) splitter is a type of polarization maintaining optical power management device that is fabricated using silica optical waveguide technology. PM PLC splitter maintains polarization of input optical signal. Polarization Maintaining Fiber Splitter is an optical splitter in which the polarization of linearly polarized light waves launched into the fiber is maintained during propagation, with little or no cross−coupling of optical power between the polarization modes.


    Features

    Low Insertion Loss

    High Return Loss

    High Extinction Ratio

    Applications

    Fiber Amplifier

    Power Monitoring

    Fiber Optical Instrument

     

    Specifications

    Parameters

    Unit

    Values

    Type

    /

    1x4

    2x4

    1x8

    2x8

    1x16

    2x16

    1x32

    Center Wavelength

    nm

    1310, 1550

    Operating Wavelength Range

    nm

    ±40

    Insertion Loss

    dB

    ≤7.3

    ≤7.8

    ≤10.5

    ≤11.2

    ≤13.7

    ≤14.6

    16.9

    Uniformity

    dB

    ≤0.6

    ≤1.0

    ≤0.8

    ≤1.2

    ≤1.2

    ≤1.5

    ≤1.5

    Extinction Ratio


    ≥18

    Coupling Ratio

    %

    Equal splitting ratio

    Axis Alignment

    /

    Both axis working

    Return Loss

    dB

    ≥50

    Max Power Handling (CW)

    mW

    500

    Tensile Load

    N

    ≤5

    Operating Temperature

    -5~+75

    Storage Temperature

    -40~+85

    Package Dimension (bare fiber)

    mm

    4x4x40

    4x4x55

    4x4x40

    4x4x55

    4x7x50

    4x7x60

    4x7x50

    Package Dimension (Mini Module) tube)

    mm

    4x7x60

    4x12x60

    4x7x60

    4x12x60

    4x12x60

    4x12x60

    6x20x80

    Package Dimension (ABS Box type)

    mm

    100x80x10

    100x80x10

    100x80x10

    100x80x10

    120x80x18

    120x80x18

    120x80x18

    Note:

    1. Above specifications are for device without connector, If with connector, IL will be 0.3dB higher, return loss with be reduce 5dB and Extinction Ratio will reduce 2dB.

    2. The PM PLC Splitter Module is box axis working, no axis can be blocked; default test extinction ratio is on the slow axis. All parameters are tested at room temperature at central wavelength only.

     

    Drawing

    1xN

    1xN.png

     

     

    Ordering Information  PMPLC-XXXX-XX-XX-XX-XX-XX-XX

    ①Wavelength:

    1310=1310nm; 1550=1550nm; S=Specify

    ②Configuration Type:

    104=1x4; 108=1x8; 116=1x16; 132=1x32; S=Specify

    ③Fiber Type:

    PM1310; PM1550; S=Specify

    ④Package Type:

    P1=bare type; P2=Mini Module; P3=ABS Box; S=Specify

    ⑤Pigtail Type:

    00=bare fiber;  09=900um loose tube; 20=2.0mm cable; 30=3.0mm cable

    ⑥Fiber Length:

    08=0.8m; 10=1m; S=Specify

    ⑦Connector Type:

    FA=FC/APC; FP=FC/UPC; SA=SC/APC; SP=SC/UPC; S=Specify

     


    • verification code